  Datasheet File OCR Text:
  SC942900 90-240vac/dc control 25a/230vac output all technical caracteristics are subject to change without previous notice. caract?ristiques sujettes ? modifications sans pr?avis. p p p p r r r r o o o o u u u u d d d d t t t t o o o o s s s s e e e e r r r r v v v v e e e e y y y y o o o o u u u u application typique/ typical application ? 12-280vac -25a zero-cross ac output. ? ip20 protection optional (1k460000). ? designed for resistive loads. ?sortie ac synchrone : 12-280vac-25a ?possibilit? de protection ip20 en option : capot 1k460000 ?adapt? aux charges r?sistives page 1 /2 f/gb s/mon/SC942900/a/1/02/2000 caract?ristiques de commande (? 20 c) / control characteristics (at 20 c) ac/dc param?tre / parameter symbol min nom max unit tension de commande / control voltage uc 90 240 v courant de commande / control current (@ uc ) ic 3 8 ma tension de relachement/ release voltage uc off 15 v r?sistance interne / input internal resistor fig.1 rc 30 k ? caract?ristiques d'entr?e-sortie (? 20 c) / input-output characteristics (at 20 c) isolement entr?e-sortie/ input-output isolation @500m ui 4000 vrms isolement sortie-semelle/ output-case isolation @500m ui 2500 vrms tension assign?e isolement/rated impulse voltage uimp 4000 v caract?ristiques g?n?rales / general characteristics param?tre / parameter conditions symbol typ. unit poids/ weight 90 g plage de temp?rature de stockage / storage temperature range -40 / +100 c plage de temp?rature de fonctionnement/ operating temperature range -40 / +100 c fig1 : caract?ristique d'entr?e / control characteristic 0 20 40 60 80 100 120 140 160 180 200 220 240 0 0 2 4 6 8 0 uc (v) ic (ma) relais statique monophas? de puissance power solid state relay celduc ? r e l a i s t o leran c e s : 0,3 1 2 43 28 4,7 43,2 47,6 7,5 5,1 25,4 44,5 m4 m3 58,2 27 19,6 22,8 ?,5 25,8 entr?e control 90-240vac protect i on r?seau line protection 12 - 280 v ac 1 2 * 1-2 peuvent ?tre invers?es/ 1 -2 can be changed * le relais doit ?tre mont? sur dissipateur thermique / ssr must be mounted on a heatsink * option : couvercle de protection des bornes : 1k460 000 / cover : 1k460 000 c h a r g e / lo a d = fig. 1 :caract?ristique d'entr?e / control characteristic dimensions/ size
rms load current : i (a) ambient temperature : tamb (?) 02468101214161820222426 0 0 5 10 15 20 25 30 35 40 0 pd ( watts) 0 10 2 03040 5 060 7 0 80 90 100 110 120 0 t case max (?) 70 90 100 0,95k/w 0,75k/w 6k/w 80 full on state 50% on state 1,6k/w 1,1k/w 2,2k/w s/mon/SC942900/a/1/02/2000 caract?ristiques de sortie(? 20 c) / output characteristics (at 20 c) param?tre / parameter conditions symbol typ. unit tension de charge / load voltage ue 230 v rms plage tension de fonctionnement / operating range uemin-max 12-280 v rms tension cr?te / peak voltage up 600 v niveau de synchonisation / synchronizing level usync 12 v tension d'amor?age / latching voltage ie nom ua 8 v courant nominal ac-51/ ac-51 nominal current ( see fig. 2 ) ie ac-51 25 a rms courant nominal ac-53/ ac-53 nominal current * courant de surcharge non r?p?titif / non repetitive overload current tp=10ms (fig. 3) itsm 240 a chute tension directe cr?te/ on state voltage drop @ ie nom vd 1,2 v courant de fuite ?tat bloqu?/ off state leakage current @ue, 50hz ilk <3 ma courant de charge minimum / minimum load current ie min 5 ma temps de fermeture/ turn on time uc nom dc ,f=50hz ton max 30 ms temps d'ouverture/ turn off time uc nom dc ,f=50hz toff max 30 ms plage de fr?quence / operating frequency range f 0,1-440 hz dv/dt ?tat bloqu? / off state dv/dt dv/dt 500 v/ s di/dt maximum non r?p?titif/ maximum di/dt non repetitive di/dt 50 a/ s i 2 t (<10ms) i 2 t 288 a 2 s emc test d'immunit? conduite / conducted immunity level iec 1000-4-4 (burst) 2kv criterion b emc test d'immunit? conduite / conducted immunity level iec 1000-4-5(schocks) 2kv crit.a with external vdr conformit? / conformity en60947-4-x 1 10 1 0,1 0,01 0 50 100 150 200 250 0 t(s ) itsm (apeak) surcharge de courant : itsm (apeak) = f(t) pour mod?le 25a(itsm=230a) surge current : itsm (apeak) = f(t) for 25a models with itsm =230a surcharge de courant non r?p?titive sans tension r?appliqu?e / no repetive surge current without voltage reapplied. surcharge de courant r?p?titive avec tension r?appliqu? e repetive surge current with voltage reapplied. fig.3 1 -itsm non r?p?titif sans tension r?appliqu?e est donn? pour la d?termination des protections. no repetitive itsm is given without voltage reapplied for the determination of the protection. 2 -itsm r?p?titif est donn? pour des surcharges de courant (tj initiale=70 c). la r?p?tition de ces surcharges de courant diminue la dur?e de vie du relais. repetitive itsm is given for inrush current with initial tj = 70 c. the repetition of the surge cur- rent decrease the lifetime ssr's . r e l a i s rue amp?re b.p. 4 42290 sorbiers - france e-mail : celduc-relais@celduc.com fax +33 (0) 4 77 53 85 51 service commercial france t?l. : +33 (0) 4 77 53 90 20 sales dept.for europe tel. : +33 (0) 4 77 53 90 21 sales dept. asia : t?l. +33 (0) 4 77 53 90 19 www.celduc.com celduc ? pr?cautions : * les relais ? semiconducteurs ne procurent pas d'isolation gal- vanique entre le r?seau et la charge. cautions : * semiconductor relays don't provide any galvanic insulation between the load and the mains. page 2 / 2 f/gb fig. 2 courbes thermiques / thermal characteristics * for other loads consult celduc pour autres charges consulter celduc


▲Up To Search▲   

 
Price & Availability of SC942900

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X